For pipe heat tracing it is convenient to think of the heat loss and respective heat required in Watts per unit length. Most pipe heat loss calculations are done with a per meter basis. Then it is only a matter of selecting a heating cable with this watt per unit output or higher.

19.03.2015

Two different parallel watt density cables may be spliced together. Being parallel, the power out put in the two spliced sections will be different as rated. Care must be taken to not exceed the maximum circuit length and circuit breaker rating. The simple solution in this case is to use the maximum circuit length of the higher wattage cable.

19.03.2015

When the controller fails and the heating cable remains energized the pipe will increase in temperature to an equilibrium temperature. This is called “run-a-away” temperature. For stabilized designs in hazardous areas, the condition is used to determine the maximum heating cable sheath temperature.

19.03.2015

While thermal insulations have thermal conductivities, or k-factors, that reduce the flow of heat, the k-factors vary depending on the specific thermal insulation type. They also have different maximum temperature ratings. These factors must be addressed in a heat tracing design.

19.03.2015

Typically not, because most of the reduction in heat loss is through the thermal insulation. The increase for this change in wind speed may be only 2-5%.

19.03.2015

Typically not. Heat tracing is primarily used for temperature maintenance. Heat-ups in short periods of time (minutes to a few hours) will most likely require more heat than that needed to maintain the temperature at the desired temperature above ambient.

19.03.2015

This is a common term as it relates to thermodynamics and heat transfer calculations.
It is a state of thermal dynamics where the stabilized temperature is a result of the heat input equal to the heat loss.

28.05.2013

For accurate SO2 measurement a testo fluegas analyser must always be equipped with a SO2 and NO2 cell. NO2 has a negative impact on the SO2 reading by 110%. If the analyser measures NO2, it will automatically compensate for this. If not, then the SO2 reading might be far out depending on NO2 in the flue gas.

15.05.2013

We offer a wide range of heat tracing cables & offer design services for completed solutions.

Find more info. Contact our consulting engineers


 

...

06.05.2013

Installing the cable on top or directly at the bottom of a pipe is not recommended as it could result in mechanical damage to the cable.

On top of the pipe the cable is susceptible to personnel walking on cable.

When installed on the bottom of the pipe, damage may be caused by placing the pipe with the cable in a pipe rack. The ideal location is at 5 or 7 o’clock. Locating the cable at 2 or 10 o’clock is acceptable. Installation ease should dictate the selection of these...